This chapter presents an optimization framework to manage green datacenters using multilevel energy reduction techniques in a joint approach. A green datacenter exploits renewable energy sources and active Uninterruptible Power Supply (UPS) units to reduce the energy intake from the grid while improving its Quality of Service (QoS) . At server level, the state-of-the-art correlation-aware Virtual Machines (VMs) consolidation technique allows to maximize server’s energy efficiency. At system level, heterogeneous Energy Storage Systems (ESS) replace standard UPSs, while a dedicated optimization strategy aims at maximizing the lifetime of the battery banks and to reduce the energy bill , considering the load of the servers. Results demonstrate, under different number of VMs in the system, up to 11.6% energy savings, 10.4% improvement of QoS compared to existing correlation-aware VM allocation schemes for datacenters and up to 96% electricity bill savings.
Joint Computing and Electric Systems Optimization for Green Datacenters / Pahlevan, Ali; Rossi, Maurizio; Pablo, G. Del Valle; Brunelli, Davide; Atienza, David. - STAMPA. - (2016), pp. 1-21. [10.1007/978-94-017-7358-4_35-1]
Joint Computing and Electric Systems Optimization for Green Datacenters
Rossi, Maurizio;Brunelli, Davide;
2016-01-01
Abstract
This chapter presents an optimization framework to manage green datacenters using multilevel energy reduction techniques in a joint approach. A green datacenter exploits renewable energy sources and active Uninterruptible Power Supply (UPS) units to reduce the energy intake from the grid while improving its Quality of Service (QoS) . At server level, the state-of-the-art correlation-aware Virtual Machines (VMs) consolidation technique allows to maximize server’s energy efficiency. At system level, heterogeneous Energy Storage Systems (ESS) replace standard UPSs, while a dedicated optimization strategy aims at maximizing the lifetime of the battery banks and to reduce the energy bill , considering the load of the servers. Results demonstrate, under different number of VMs in the system, up to 11.6% energy savings, 10.4% improvement of QoS compared to existing correlation-aware VM allocation schemes for datacenters and up to 96% electricity bill savings.File | Dimensione | Formato | |
---|---|---|---|
ALI-Rossi-Springer-Chaprte-2017.pdf
Solo gestori archivio
Tipologia:
Versione editoriale (Publisher’s layout)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
771.76 kB
Formato
Adobe PDF
|
771.76 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione