One of the design goals of the neutron time-of-flight (TOF) diffractometer HIPPO (HIgh Pressure - Preferred Orientation) at LANSCE (Los Alamos Neutron Science Center) was efficient quantitative texture analysis. In this paper, the effects of the HIPPO detector geometry and layout on texture analysis, particularly the shape and dimensions of the detector panels, are investigated. An aluminum sample with a strong and asymmetric texture was used to determine the methodological limitations of various methods of quantitative texture analysis. Several algorithms for extracting the orientation distribution function (ODF) from the TOF-spectra are compared: discrete orientations at arbitrary positions, harmonic method in Rietveld codes (MAUD and GSAS) and discrete methods in MAUD. All methods provide a similar representation of the main texture component, but discrete methods have a fundamental advantage over harmonic methods in characterizing regions of the ODF with low orientation densities. For HIPPO data of the present sample, harmonic expansions beyond 1(max) = 12 introduce subsidiary maxima and minima, which are consistently identified as artifacts. The results of our analysis establishes HIPPO as an efficient instrument to quantitatively determine preferred orientations in relatively short measuring times, if the texture features are not exceedingly sharp (full-width at half-maximum (FWHM) in the ODF > 20-30).

Quantitative Texture Analysis with the Hippo TOF Diffractometer / J., Pehl; S., Matthies; H., Wenk; Lutterotti, Luca; S. C., Vogel. - STAMPA. - 495-497:(2005), pp. 113-118. [10.4028/www.scientific.net/MSF.495-497.113]

Quantitative Texture Analysis with the Hippo TOF Diffractometer

Lutterotti, Luca;
2005-01-01

Abstract

One of the design goals of the neutron time-of-flight (TOF) diffractometer HIPPO (HIgh Pressure - Preferred Orientation) at LANSCE (Los Alamos Neutron Science Center) was efficient quantitative texture analysis. In this paper, the effects of the HIPPO detector geometry and layout on texture analysis, particularly the shape and dimensions of the detector panels, are investigated. An aluminum sample with a strong and asymmetric texture was used to determine the methodological limitations of various methods of quantitative texture analysis. Several algorithms for extracting the orientation distribution function (ODF) from the TOF-spectra are compared: discrete orientations at arbitrary positions, harmonic method in Rietveld codes (MAUD and GSAS) and discrete methods in MAUD. All methods provide a similar representation of the main texture component, but discrete methods have a fundamental advantage over harmonic methods in characterizing regions of the ODF with low orientation densities. For HIPPO data of the present sample, harmonic expansions beyond 1(max) = 12 introduce subsidiary maxima and minima, which are consistently identified as artifacts. The results of our analysis establishes HIPPO as an efficient instrument to quantitatively determine preferred orientations in relatively short measuring times, if the texture features are not exceedingly sharp (full-width at half-maximum (FWHM) in the ODF > 20-30).
2005
J., Pehl; S., Matthies; H., Wenk; Lutterotti, Luca; S. C., Vogel
Quantitative Texture Analysis with the Hippo TOF Diffractometer / J., Pehl; S., Matthies; H., Wenk; Lutterotti, Luca; S. C., Vogel. - STAMPA. - 495-497:(2005), pp. 113-118. [10.4028/www.scientific.net/MSF.495-497.113]
File in questo prodotto:
File Dimensione Formato  
MSF.495-497.113.pdf

Solo gestori archivio

Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.62 MB
Formato Adobe PDF
1.62 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/45540
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact