An analytical procedure consisting of ultrasonic extraction with acetonitrile, trimethylsilylation and GC-MS analysis was applied to the determination of levoglucosan (LG) in aerosol collected with three different filter types (teflon, quartz, glass). Methyl-β-l-arabinopyranoside (MA) and sedoheptulosan (SD, 2,7-anhydro-β-d-altro-heptulopyranose) were investigated as recovery standards. Mean recovery of MA decreased in the order 82%, 78%, 74% and that of SD from 82% to 76% and 32% from teflon, quartz and glass blank filters, respectively, whereas recovery of LG was little affected (80-86%). The extraction efficiency from glass filters could be increased by using methanol in place of acetonitrile, but recovery of SD remained inadequate. Internal calibration with MA was linear in the 0.035-70 μg mL-1 LG concentration interval. The method was tested on different air filter materials utilized to sample PM10 in outdoor air and wood smoke emitted from stove and boiler encompassing LG concentrations from 0.06 to 230 μg m-3 with RSD in the 2.9-22% range. The application of the method in aerosol sampled in alpine zones of Italy revealed a linear correlation between LG and PM10 concentrations with a higher proportion of LG in winter and in rural areas where the use of woody biomass for residential heating is widespread.

GC-MS determination of levoglucosan in atmospheric particulate matter collected over different filter materials / Fabbri, D.; Modelli, S.; Torri, C.; Cemin, A.; Ragazzi, M.; Scaramuzza, P.. - In: JOURNAL OF ENVIRONMENTAL MONITORING. - ISSN 1464-0333. - ELETTRONICO. - 2008,10:12(2008), pp. 1519-1523. [10.1039/b808976k]

GC-MS determination of levoglucosan in atmospheric particulate matter collected over different filter materials

Cemin A.;Ragazzi M.;
2008-01-01

Abstract

An analytical procedure consisting of ultrasonic extraction with acetonitrile, trimethylsilylation and GC-MS analysis was applied to the determination of levoglucosan (LG) in aerosol collected with three different filter types (teflon, quartz, glass). Methyl-β-l-arabinopyranoside (MA) and sedoheptulosan (SD, 2,7-anhydro-β-d-altro-heptulopyranose) were investigated as recovery standards. Mean recovery of MA decreased in the order 82%, 78%, 74% and that of SD from 82% to 76% and 32% from teflon, quartz and glass blank filters, respectively, whereas recovery of LG was little affected (80-86%). The extraction efficiency from glass filters could be increased by using methanol in place of acetonitrile, but recovery of SD remained inadequate. Internal calibration with MA was linear in the 0.035-70 μg mL-1 LG concentration interval. The method was tested on different air filter materials utilized to sample PM10 in outdoor air and wood smoke emitted from stove and boiler encompassing LG concentrations from 0.06 to 230 μg m-3 with RSD in the 2.9-22% range. The application of the method in aerosol sampled in alpine zones of Italy revealed a linear correlation between LG and PM10 concentrations with a higher proportion of LG in winter and in rural areas where the use of woody biomass for residential heating is widespread.
2008
12
Fabbri, D.; Modelli, S.; Torri, C.; Cemin, A.; Ragazzi, M.; Scaramuzza, P.
GC-MS determination of levoglucosan in atmospheric particulate matter collected over different filter materials / Fabbri, D.; Modelli, S.; Torri, C.; Cemin, A.; Ragazzi, M.; Scaramuzza, P.. - In: JOURNAL OF ENVIRONMENTAL MONITORING. - ISSN 1464-0333. - ELETTRONICO. - 2008,10:12(2008), pp. 1519-1523. [10.1039/b808976k]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11572/208750
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 18
social impact